Switching Power Supply 400W DC12V/24V/36V/48V/60V 8.3A-33.3A Support Monitoring Transformer LED Lighting

$44.99

  • Product Code: ED0000906
  • Availability: In Stock
  • Ex Tax: $44.99

Available Options

Tags: Switching Power Supply

Feature:
Model: YY-400-xx
Output power: 400W
Output voltage: DC12/24/36/48/60V (Optional)
Input voltage: 110V/220V AC
Ambient temperature: -10 ° C ~ +50 ° C
Adjustable voltage: ±10%
Product size: 215 x 115 x 50mm

Item Technical Specifications
Output DC voltage 12V 24V 36V 48V 60V
Rated current 33.3A 16.6A 11.1A 8.3A 6.6A
Rated power 399.6W 398.4W 399.6W 398.4W 396W
Ripple and noise ① <150mV <150mV <240mV <240mV <240mV
Voltage accuracy ±1%
Output voltage adjustment range ±10%
Load Regulation <±1.2% <±1% <±0.5% <±0.5% <±0.5%
Linear adjustment rate <±1%
Input Voltage range 90-132VAC/180-264VAC 47Hz~63Hz; 254VDC~370VDC
Efficiency (typical) ② >82% >84% >86% >86% >86%
Working current <5.2A 115VAC, <2.8A 230VAC
Electric shock 110VAC: 25A, 220VAC: 50A
Start, rise, hold time 200ms, 50ms, 20ms: 230VAC
Protection Overload protection 105%-135% type: constant current output, +V0 falls to undervoltage point to cut off output, reset: power on again
Overvoltage protection Turn off output when >=115%-145%
Undervoltage protection Turn off output when <10%-45%
Short circuit protection Close output
Over temperature protection RTH3:>=65°C fan starts, <=55°C fan off, >=80°C off output (5V-15V)
RTH3:>=70°C fan starts, <=60°C fan off, >=85°C off output (18V-48V)
Environment Working temperature, humidity -10°C ~+50°C, 20% ~90%RH
Storage temperature, humidity -20°C ~+85°C, 10%~95%RH
Safety Withstand voltage Input-Output: 1.5KVAC
Input - Enclosure: 1.5KVAC
Output - Enclosure: 0.5KVAC for 1 minute
Leakage current Input-output <6mA at 1.5KVAC
Leakage current Input-output <1.5mA at 220VAC
Isolation resistance Input-output, input-housing, output-housing: 500VDC/100MΩ
Other Size 215*115*50mm
Net reset / gross reset 874.1/936.3g

①Ripple and noise measurement method: Use a 12mm twisted pair cable, and the terminal should be connected with 0.1uF and 47uF
capacitors in parallel and measure at 20MHz bandwidth.
②Efficiency is tested at an input voltage of 230VAC, rated load, and ambient temperature of 25°C.
Accuracy: Includes setting error, linear adjustment rate and load adjustment rate.
Linear Rate Test Method: Test from low voltage to high voltage at rated load.
Load regulation test method: from 0% to 100% of rated load.
The startup time is measured in the cold start state. The fast and frequent switching machine may increase the startup time. When the
operating altitude is higher than 2000M, the operating environment temperature should be reduced by 5°C/1000M.

Package includes:

1 x Power Supply



Switching-Power-Supply-400W-DC12V24V36V48V60V-83A-333A-Support-Monitoring-Transformer-LED-Lighting-1610011

Switching-Power-Supply-400W-DC12V24V36V48V60V-83A-333A-Support-Monitoring-Transformer-LED-Lighting-1610011

Switching-Power-Supply-400W-DC12V24V36V48V60V-83A-333A-Support-Monitoring-Transformer-LED-Lighting-1610011

Switching-Power-Supply-400W-DC12V24V36V48V60V-83A-333A-Support-Monitoring-Transformer-LED-Lighting-1610011

Switching-Power-Supply-400W-DC12V24V36V48V60V-83A-333A-Support-Monitoring-Transformer-LED-Lighting-1610011

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha