Feature:
Model: YY-400-xx
Output power: 400W
Output voltage: DC12/24/36/48/60V (Optional)
Input voltage: 110V/220V AC
Ambient temperature: -10 ° C ~ +50 ° C
Adjustable voltage: ±10%
Product size: 215 x 115 x 50mm
Package includes:
1 x Power Supply
Item | Technical Specifications | ||||||
Output | DC voltage | 12V | 24V | 36V | 48V | 60V | |
Rated current | 33.3A | 16.6A | 11.1A | 8.3A | 6.6A | ||
Rated power | 399.6W | 398.4W | 399.6W | 398.4W | 396W | ||
Ripple and noise ① | <150mV | <150mV | <240mV | <240mV | <240mV | ||
Voltage accuracy | ±1% | ||||||
Output voltage adjustment range | ±10% | ||||||
Load Regulation | <±1.2% | <±1% | <±0.5% | <±0.5% | <±0.5% | ||
Linear adjustment rate | <±1% | ||||||
Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz; 254VDC~370VDC | |||||
Efficiency (typical) ② | >82% | >84% | >86% | >86% | >86% | ||
Working current | <5.2A 115VAC, <2.8A 230VAC | ||||||
Electric shock | 110VAC: 25A, 220VAC: 50A | ||||||
Start, rise, hold time | 200ms, 50ms, 20ms: 230VAC | ||||||
Protection | Overload protection | 105%-135% type: constant current output, +V0 falls to undervoltage point to cut off output, reset: power on again | |||||
Overvoltage protection | Turn off output when >=115%-145% | ||||||
Undervoltage protection | Turn off output when <10%-45% | ||||||
Short circuit protection | Close output | ||||||
Over temperature protection |
RTH3:>=65°C fan starts, <=55°C fan off, >=80°C off output (5V-15V) RTH3:>=70°C fan starts, <=60°C fan off, >=85°C off output (18V-48V) |
||||||
Environment | Working temperature, humidity | -10°C ~+50°C, 20% ~90%RH | |||||
Storage temperature, humidity | -20°C ~+85°C, 10%~95%RH | ||||||
Safety | Withstand voltage |
Input-Output: 1.5KVAC Input - Enclosure: 1.5KVAC Output - Enclosure: 0.5KVAC for 1 minute |
|||||
Leakage current | Input-output <6mA at 1.5KVAC | ||||||
Leakage current | Input-output <1.5mA at 220VAC | ||||||
Isolation resistance | Input-output, input-housing, output-housing: 500VDC/100MΩ | ||||||
Other | Size | 215*115*50mm | |||||
Net reset / gross reset | 874.1/936.3g |
①Ripple and noise measurement method: Use a 12mm twisted pair cable, and the terminal should be connected with 0.1uF and 47uF
capacitors in parallel and measure at 20MHz bandwidth.
capacitors in parallel and measure at 20MHz bandwidth.
②Efficiency is tested at an input voltage of 230VAC, rated load, and ambient temperature of 25°C.
Accuracy: Includes setting error, linear adjustment rate and load adjustment rate.
Linear Rate Test Method: Test from low voltage to high voltage at rated load.
Load regulation test method: from 0% to 100% of rated load.
The startup time is measured in the cold start state. The fast and frequent switching machine may increase the startup time. When the
operating altitude is higher than 2000M, the operating environment temperature should be reduced by 5°C/1000M.
operating altitude is higher than 2000M, the operating environment temperature should be reduced by 5°C/1000M.
Package includes: